Epoxy Body Bulb Electrode – FLS pH/ORP 200
The FLS line of pH and ORP electrodes offers a cost-effective, multi-purpose solution for in-line or submersion measurements across a wide range of applications. Available in single and double junction versions, these electrodes can be supplied with or without quick-disconnect top caps. For automatic temperature compensation (ATC), a pH model with an integrated temperature sensor is also available.
Constructed with durable epoxy bodies, these electrodes deliver excellent chemical resistance, making them suitable for varied applications. Installation is simple—economic in-line mounting can be achieved with a reusable gland, while submersion mounting requires only a ½” or ¾” coupler with pipe extension. A special version is also designed for direct installation on FLS T-fittings or FLS clamp saddles with just the addition of a nut.
Epoxy Body Bulb Electrode – FLS pH/ORP 200
The FLS line of pH and ORP electrodes offers a cost-effective, multi-purpose solution for in-line or submersion measurements across a wide range of applications. Available in single and double junction versions, these electrodes can be supplied with or without quick-disconnect top caps. For automatic temperature compensation (ATC), a pH model with an integrated temperature sensor is also available.
Constructed with durable epoxy bodies, these electrodes deliver excellent chemical resistance, making them suitable for varied applications. Installation is simple—economic in-line mounting can be achieved with a reusable gland, while submersion mounting requires only a ½” or ¾” coupler with pipe extension. A special version is also designed for direct installation on FLS T-fittings or FLS clamp saddles with just the addition of a nut.
Technical Details of Epoxy Body Bulb Electrode – FLS pH/ORP 200
| Specification | Details |
|---|---|
| Operating Range | – pH Electrodes: 0 – 14 pH (0 – 12.3 pH without Na+ error) – ORP Electrodes: ± 2000 mV |
| Temperature Compensation Device (for TC model) | PT1000 |
| Pipe Size Range | DN15 to DN100 (0.5” to 4”) |
| Zero Voltage Point New Electrode Performances | 7.00pH ± 0.2pH |
| Efficiency New Electrode Performances | > 97% @ 25°C (77°F) |
| Response Time New Electrode Performances | – pH: 2 sec for 95% of signal change – ORP: Application dependent |
| Reference Electrolyte | Solidified gel 3.5M KCl for single junction versions KCl-KNO3 for double junction versions |
| Process Connection | – In-line installation with threaded nipple ½”, ¾” or PG13,5 – FLS installation fittings – Submersible installation |
| Max Working Pressure / Working Temperature | – 7 bar (100 psi) @ 25°C (77°F) – 1 bar (14.5 psi) @ 65°C (149°F) |
| Wetted Materials | – Body: Epoxy – O-ring Junction: Silicone – Junction: Pellon® – Sensing Surface: Glass membrane (pH), Platinum (ORP) |
| O-ring | NBR (PH222 CD, PH223 CD, ORP222 CD, ORP223 CD) |
| Manufactured under | ISO 9001, ISO 14001 |
| Certifications | CE, EAC |
| Model | Body | Junction material/type | Reference solution | Sensing surface | O-ring | Connection | Max working pressure |
|---|---|---|---|---|---|---|---|
| PH200C | epoxy | nylon/S.J. | 3.5M KCl | glass membrane | - | 5 mt. (16.5 ft.) Cable | 7 bar @ 25°C / 1 bar @ 65°C (100 psi @ 77°F / 14.5 psi @ 149°F) |
| PH222CD | epoxy | nylon/D.J. | 3.5M KCl / Sat’d KNO₃ | glass membrane | silicone | Twist-Lock (BNC) | same as above |
| PH223CD | epoxy | nylon/D.J. | 3.5M KCl / Sat’d KNO₃ | glass membrane | silicone | Twist-Lock (BNC) | Same as above |
| ORP200C | epoxy | nylon/S.J. | 3.5M KCl | platinum | - | 5 mt. (16.5 ft.) Cable | same as above |
| ORP222CD | epoxy | nylon/D.J. | 3.5M KCl / Sat’d KNO₃ | platinum | silicone | Twist-Lock (BNC) | same as above |
| ORP223CD | epoxy | nylon/D.J. | 3.5M KCl / Sat’d KNO₃ | platinum | silicone | Twist-Lock (BNC) | same as above |
| PH222CDTC | epoxy | nylon/D.J | 3.5M KCl / Sat’d KNO₃ | glass membrane | - | 5 mt. (16.5 ft.) Cable | same as above |
A → PH200C, PH222CDTC, ORP200C
B → PH222CD, ORP222CD
C → PH223CD, ORP223CD
1 → Cable: 5 mt (6.5 ft.)
2 → Epoxy body
3 → pH glass bulb
4 → BNC connector
5 → Buna-N O-rings
6 → FPM O-rings

Customization & Processing Options
Customizations Option Available for Epoxy Body Bulb Electrode – FLS pH/ORP 200
At Petron Thermoplast, we offer customized PVDF fittings to meet your specific system requirements.
Customization options include:
- Tailor-made dimensions and wall thicknesses
- Custom-molded and machined PVDF fittings
- Pre-fabricated manifolds and assemblies
- Choice of connection type (butt fusion, socket fusion, or flanged)
- OEM branding or marking options